PD4-E CANopen Online Manual

605Dh Halt Option Code

Function

The object contains the action that is to be executed if bit 8 (Halt) is set in controlword 6040h.

Object description


Index 605Dh
Object name Halt Option Code
Object Code VARIABLE
Data type INTEGER16
Savable yes, category: application
Access read / write
PDO mapping no
Allowed values  
Preset value 0001h
Firmware version FIR-v1426
Change history  

Description


Value Description
-32768 … 0 Reserved
1 Braking with "slow down ramp" (deceleration (deceleration ramp) depending on operating mode)
2 Braking with "quick stop ramp" (deceleration (deceleration ramp) depending on operating mode)
3 … 32767 Reserved

▶   next

Contents





Privacy settings
We use essential cookies that our website requires to function correctly. With your consent, we also use optional cookies for statistics and marketing. You can agree to the non‑essential cookies by clicking the "Accept" button or reject them. You can call up your settings and also withdraw your consent at any time. For more information, see our privacy statement.