PD4-E CANopen Online-Handbuch

2030h Pole Pair Count

Funktion

Enthält die Polpaarzahl des angeschlossenen Motors.

Objektbeschreibung


Index 2030h
Objektname Pole Pair Count
Object Code VARIABLE
Datentyp UNSIGNED32
Speicherbar ja, Kategorie: Tuning
Zugriff lesen/schreiben
PDO-Mapping nein
Zulässige Werte  
Vorgabewert
  • PD4-E591L42-E-65-2: 00000032h
  • PD4-E601L42-E-65-2: 00000032h
  • PD4-EB59CD-E-65-2: 00000003h
Firmware Version FIR-v1426
Änderungshistorie

Firmware Version FIR-v1540: Eintrag "Saveable" geändert von "nein" auf "ja, Kategorie: Tuning".


▶   next

Contents





Privacy settings
We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. Use necessary cookies only.