NP5 CANopen Online Manual

CANopen

Before starting commissioning, we recommend reading chapters Connecting the controller and CANopen configuration.

  1. Connect the CANopen master to the controller via the CAN+, CAN- cables. Check the connection of your CAN-GND and that the necessary 120 ohm termination resistor is present between CAN+ and CAN-.
  2. Supply the controller with voltage.
  3. Change the configuration values if necessary, see CANopen configuration.
    The controller is set ex works to node-ID 1, baud rate 1 Mbaud.
  4. To test the interface, send bytes 40 41 60 00 00 00 00 00 to the controller.
    Statusword (6041h) was read; you receive this response: 4B 41 60 00 XX XX 00 00 .
▶   next

Contents



Privacy settings
We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. Use necessary cookies only.