CL3-E CANopen/USB Technical Manual

2200h Sampler Control

Function

Controls the installed sampler used to cyclically record any values from the "Dictionary" object.

Object description


Index 2200h
Object Name Sampler Control
Object Code VARIABLE
Data type UNSIGNED32
Saveable yes, category: application
Access Read/write
PDO Mapping RX - PDO
Admissible Values  
Specified Value 00000000h
Firmware Version FIR-v1426
Change History

Firmware Version FIR-v1626: Entry "Saveable" modified from "No" to "yes, category: application".


Description

ON
Value = "1": The sampler will be activated
▶   next