Magnetic encoders  –  Products

NME1

NME1 – Magnetic encoder

Encoder for stepper and BLDC motors with 1,024 pulses per revolution (4,096 increments with quadrature). Precise speed and position control due to a resolution of 0.09°.
  • Encoder Resolution 1024 CPR
  • Operating Voltage (Encoder) 5.00 – 24.00 V
  • Index  
  • Line Driver  
  • Shaft Diameter  -
magnetic encoder with high resolution

NME2 – High-resolution magnetic encoder

The very high resolution of the NME2 encoder allows for very accurate positioning and excellent speed control, even at low speeds.
  • Encoder Resolution 4096 CPR - 16384 CPR
  • Operating Voltage (Encoder) 4.50 – 5.50, 9.00 – 30.00 V
  • Index / 
  • Line Driver / 
  • Shaft Diameter  -
NME3

NME3 – Compact magnetic encoder

This encoder is available in a version for incremental signals as well as with an SSI interface. It is especially designed for speed control applications.
  • Encoder Resolution 500 CPR - 4096 CPR
  • Operating Voltage (Encoder) 4.50 – 5.50, 9.00 – 30.00 V
  • Index / 
  • Line Driver / 
  • Shaft Diameter  -

Magnetic encoders  –  Filter

Please wait while productfinder is loading ...

{{ curve.panelTitle }}

Recommended load limit:
Maximum short-term static load that may be reached when the service life is taken into account.
Recommended load limit
Continuous Operation
Torque [Nm] at {{ curve.comparePoint | number : 2 }} rpm Speed [rpm] at {{ curve.comparePoint | number : 2 }} Nm
{{ dataRow.max_power }}A {{ dataRow.voltage }}V {{ dataRow.wiring }}
 
 
 
{{ curve.calculateValueAtComparePoint(dataRow) }}
  • {{ attribute.label }}

{{ curve.panelTitle }}

Recommended load limit:
Maximum short-term static load that may be reached when the service life is taken into account.
Recommended load limit
Continuous Operation
Torque [Nm] at {{ curve.comparePoint | number : 2 }} rpm Speed [rpm] at {{ curve.comparePoint | number : 2 }} Nm
{{ dataRow.voltage }}V {{ dataRow.wiring }}
 
 
 
{{ curve.calculateValueAtComparePoint(dataRow) }}
  • {{ attribute.label }}

{{ curve.panelTitle }}

Recommended load limit:
Maximum short-term static load that may be reached when the service life is taken into account.
Recommended load limit
Continuous Operation
Force [N] at {{ curve.comparePoint | number : 2 }} mm/s Speed [mm/s] at {{ curve.comparePoint | number : 2 }} N
{{ dataRow.max_power }}A {{ dataRow.voltage }}V {{ dataRow.wiring }}
 
 
 
{{ curve.calculateValueAtComparePoint(dataRow) }}
  • {{ attribute.label }}
How to use the product finder Share results

{{ pfinder.totalResults }} Results

Compare

Do you have any questions?

Our sales team is happy to answer any questions you may have about our products.

Contact Sales
Privacy settings
We use essential cookies that our website requires to function correctly. With your consent, we also use optional cookies for statistics and marketing. You can agree to the non‑essential cookies by clicking the "Accept" button or reject them. You can call up your settings and also withdraw your consent at any time. For more information, see our privacy statement.